2014 Ford Transit Connect Titanium, 1.6L Eng VIN XFACTORY OEM SERVICE PROCEDURE

HVAC Control Module (With Ms-Can)

DTC INDEX

DTC Description Action
B1081:11 Left Temperature Damper Motor: Circuit Short to Ground GO to PINPOINT TEST L
B1081:12 Left Temperature Damper Motor: Circuit Short to Battery GO to PINPOINT TEST L
B1083:11 Recirculation Damper Motor: Circuit Short to Ground GO to PINPOINT TEST G
B1083:12 Recirculation Damper Motor: Circuit Short to Battery GO to PINPOINT TEST G
B1086:11 Air Distribution Damper Motor: Circuit Short to Ground GO to PINPOINT TEST H
B1086:12 Air Distribution Damper Motor: Circuit Short to Battery GO to PINPOINT TEST H
B10B8:97 Push Buttons: Component or System Operation Obstructed or Blocked
  • Buttons held too long may set this DTC.
  • ATTEMPT to clean the buttons. CLEAR the Diagnostic Trouble Codes (DTCs) and REPEAT the self-test.
  • If the DTC does not return, IGNORE the DTC and CONTINUE diagnosing other Diagnostic Trouble Codes (DTCs) or symptoms.
  • If the DTC returns, INSTALL a new HVAC control module.

    REFER to: CLIMATE CONTROL ASSEMBLY .

U0140:00 Lost Communication With Body Control Module: No Sub Type Information GO to PINPOINT TEST O
U0155:00 Lost Communication With Instrument Panel Cluster (IPC) Control Module: No Sub Type Information GO to PINPOINT TEST P
U2100:00 Initial Configuration Not Complete: No Sub Type Information
  • CHECK the service history for recent service actions related to the HVAC control module. This DTC sets due to incomplete or improper PMI procedures.
  • If there have been recent service actions with this module, REPEAT the PMI procedure using as-built data. FOLLOW the diagnostic scan tool instructions.
  • If there have been no recent service actions, INSTALL a new HVAC control module to correct the failure to retain configuration data.

    REFER to: CLIMATE CONTROL ASSEMBLY .

U2101:00 Control Module Configuration Incompatible
  • CHECK the service history for recent service actions related to the HVAC control module. This DTC sets due to incomplete or improper PMI procedures.
  • If there have been recent service actions with this module, REPEAT the PMI procedure using as-built data. FOLLOW the diagnostic scan tool instructions.
  • If there have been no recent service actions, INSTALL a new HVAC control module to correct the failure to retain configuration data. REFER to: CLIMATE CONTROL ASSEMBLY .
U3000:00 Control Module: No Sub Type Information INSTALL a new HVAC control module.
REFER to: CLIMATE CONTROL ASSEMBLY .
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.