2012 Ford Taurus SEFACTORY OEM SERVICE PROCEDURE
General Specifications
WARNING: This page is about a different car, the 2013 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
GENERAL SPECIFICATIONS
| Item | Specification |
|---|---|
| Generator (3.5L, with AC powerpoint or climate control seats) | |
| Generator pulley ratio | 2.67:1 |
| Rating | 220 amps |
| Output | 92 amps @ 580 rpm (min) to 217 amps @ 2, 000 rpm (max) |
| Generator (3.5L, without AC powerpoint or climate control seats) | |
| Generator pulley ratio | 2.67:1 |
| Rating | 200 amps |
| Output | 90 amps @ 580 rpm (min) to 209 amps @ 2, 000 rpm (max) |
| Generator (3.7L, with AC powerpoint or climate control seats) | |
| Generator pulley ratio | 2.67:1 |
| Rating | 220 amps |
| Output | 74 amps @ 550 rpm (min) to 217 amps @ 2, 000 rpm (max) |
| Generator (3.7L, without AC powerpoint or climate control seats) | |
| Generator pulley ratio | 2.67:1 |
| Rating | 200 amps |
| Output | 72 amps @ 550 rpm (min) to 209 amps @ 2, 000 rpm (max) |
| Generator (5.0L, with AC powerpoint or climate control seats) | |
| Generator pulley ratio | 2.95:1 |
| Rating | 220 amps |
| Output | 92 amps @ 525 rpm (min) to 220 amps @ 2, 000 rpm (max) |
| Generator (5.0L, without AC powerpoint or climate control seats) | |
| Generator pulley ratio | 2.95:1 |
| Rating | 200 amps |
| Output | 90 amps @ 525 rpm (min) to 211 amps @ 2, 000 rpm (max) |
| Generator (6.2L, Base) | |
| Generator pulley ratio | 2.95:1 |
| Rating | 155 amps |
| Output | 66 amps @ 525 rpm (min) to 160 amps @ 2, 000 rpm (max) |
| Generator (6.2L, Optional) | |
| Generator pulley ratio | 2.95:1 |
| Rating | 200 amps |
| Output | 90 amps @ 525 rpm (min) to 211 amps @ 2, 000 rpm (max) |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.