2012 Ford Focus L4-2.0LFACTORY OEM SERVICE PROCEDURE

Diagnostic Routine Z




Diagnostic Routine Z

Diagnostic Overview

The Remote Function Actuator (RFA) Module Does Not Respond To The Scan Tool

Refer to Wiring Diagram Set 13 for schematic and connector information Electrical Diagrams.

Refer to Wiring Diagram Set 117 for schematic and connector information Electrical Diagrams.

Normal Operation and Fault Conditions

The RFA (Remote Function Actuator) module communicates with the scan tool through the MS-CAN (Medium Speed Controller Area Network).

Visual Inspection and Diagnostic Pre-checks

Verify RJB (Rear Junction Box) fuse 2 (10A) are OK.

Pinpoint Test

1. CHECK THE RFA (Remote Function Actuator) MODULE VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

1. Ignition OFF.

2. Disconnect: RFA (Remote Function Actuator) module C4392C (blue hardshell).

3. Ignition ON.

4. Measure:

Factory service manual diagram




Is the voltage greater than 11 volts?

Factory service manual diagram





2. CHECK THE RFA (Remote Function Actuator) MODULE GROUND CIRCUIT FOR AN OPEN

1. Ignition OFF.

2. Measure:

Factory service manual diagram




Is the resistance less than 3 ohms?

Factory service manual diagram





3. CHECK THE MS-CAN (Medium Speed Controller Area Network) CIRCUITS BETWEEN THE RFA (Remote Function Actuator) MODULE AND THE DLC (Data Link Connector) FOR AN OPEN

1. Disconnect: RFA (Remote Function Actuator) module C4392D (natural hardshell).

2. Measure:

Factory service manual diagram




Are the resistances less than 3 ohms?

Factory service manual diagram





4. CHECK FOR CORRECT RFA (Remote Function Actuator) MODULE OPERATION

1. Ignition OFF.

2. Disconnect and inspect all the RFA (Remote Function Actuator) module connectors.

3. Repair:

- corrosion (install new connector or terminals- clean module pins)
- damaged or bent pins- install new terminals/pins
- pushed-out pins- install new pins as necessary

4. Reconnect the RFA (Remote Function Actuator) module connectors. Make sure they seat and latch correctly.

5. Operate the system and determine if the concern is still present.

Is the concern still present?

Factory service manual diagram




Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.