2012 Ford Fiesta S, Automatic DCT TransFACTORY OEM SERVICE PROCEDURE

Charging System DTCS

CHARGING SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) LIST

DTCs Description Source Action
P065B:09 Generator Control Circuit Range/Performance: Component Failure PCM INSTALL a new generator. Refer to Generator . CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
P065C:09 Generator Mechanical Performance: Component Failure PCM GO to Pinpoint Test D .
P0A3B:09 Generator Over Temperature: Component Failure PCM INSTALL a new generator. Refer to Generator . CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
P1794:16 Battery Voltage Circuit: Circuit Voltage Below Threshold PCM GO to Pinpoint Test B .
P1794:17 Battery Voltage Circuit: Circuit Voltage Above Threshold PCM GO to Pinpoint Test A .
U0120:13 Lost Communication with Starter/Generator Control Module: Circuit Open PCM GO to Pinpoint Test C .
U0469:09 Invalid Data Received From Starter/Generator Control Module: Component Failure PCM INSTALL a new generator. Refer to Generator . CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
U3003:16 Battery Voltage: Circuit Voltage Below Threshold PCM GO to Pinpoint Test B .
U3003:17 Battery Voltage: Circuit Voltage Above Threshold PCM GO to Pinpoint Test A .
All other DTCs - Various Modules REFER to the ELECTRONIC ENGINE CONTROLS or the INTRODUCTION - GASOLINE MODELS . If directed to this information from another service information, GO to Symptom Chart .
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.