Removal

NOTICE: If installing a new A/C (Air Conditioning) compressor due to an internal failure of the old unit, carry out the following procedures to remove contamination from the A/C (Air Conditioning) system. Failure to remove contamination will result in poor A/C (Air Conditioning) performance and/or damage to the A/C (Air Conditioning) system components.
- If A/C (Air Conditioning) flushing equipment is available, carry out flushing of the A/C (Air Conditioning) system prior to installing a new A/C (Air Conditioning) compressor. REFER to Air Conditioning (AC) System Flushing .
- If A/C (Air Conditioning) flushing equipment is not available, carry out filtering of the A/C (Air Conditioning) system after a new A/C (Air Conditioning) compressor has been installed. REFER to Refrigerant System Filtering Following Air Conditioning (AC) Compressor Installation .
- Install a new TXV (Thermostatic Expansion Valve), as directed by the A/C (Air Conditioning) flushing or filtering procedure.
- Install a new receiver/drier desiccant cartridge as directed by the A/C (Air Conditioning) flushing or filtering procedure.


1. Installation of a new receiver/drier desiccant cartridge is not required when installing a new A/C (Air Conditioning) compressor, except when there is physical evidence of a failed A/C (Air Conditioning) compressor, or damage to the receiver/drier desiccant cartridge.

Installation

NOTICE: If installing a new A/C (Air Conditioning) compressor due to an internal failure of the old unit, carry out the following procedures to remove contamination from the A/C (Air Conditioning) system. Failure to remove contamination will result in poor A/C (Air Conditioning) performance and/or damage to the A/C (Air Conditioning) system components.
- If A/C (Air Conditioning) flushing equipment is available, carry out flushing of the A/C (Air Conditioning) system prior to installing a new A/C (Air Conditioning) compressor. REFER to Air Conditioning (AC) System Flushing .
- If A/C (Air Conditioning) flushing equipment is not available, carry out filtering of the A/C (Air Conditioning) system after a new A/C (Air Conditioning) compressor has been installed. REFER to Refrigerant System Filtering Following Air Conditioning (AC) Compressor Installation .
- Install a new TXV (Thermostatic Expansion Valve), as directed by the A/C (Air Conditioning) flushing or filtering procedure.
- Install a new receiver/drier desiccant cartridge as directed by the A/C (Air Conditioning) flushing or filtering procedure.


1. Installation of a new receiver/drier desiccant cartridge is not required when installing a new A/C (Air Conditioning) compressor, except when there is physical evidence of a failed A/C (Air Conditioning) compressor, or damage to the receiver/drier desiccant cartridge.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.