2012 Ford Explorer AWD V6-3.5LFACTORY OEM SERVICE PROCEDURE

Diagnostic Routine N




Diagnostic Routine N

Diagnostic Overview

The Liftgate Trunk Module (LTM) Does Not Respond To The Scan Tool

Refer to Wiring Diagram Set 14 for schematic and connector information Electrical Diagrams.

Refer to Wiring Diagram Set 109 for schematic and connector information Electrical Diagrams.

Normal Operation and Fault Conditions

The LTM (Liftgate/Trunk Module) communicates with the scan tool through the MS-CAN (Medium Speed Controller Area Network).

Visual Inspection and Diagnostic Pre-checks

Verify BJB (Battery Junction Box) fuse 7 (30A) and BCM (Body Control Module) fuse 9 (10A) are OK.

Pinpoint Test

1. CHECK THE LTM (Liftgate/Trunk Module) VOLTAGE SUPPLY CIRCUITS FOR AN OPEN

1. Ignition OFF.

2. Disconnect: LTM (Liftgate/Trunk Module) C4174A.

3. Ignition ON.

4. Measure:

Factory service manual diagram



Factory service manual diagram




Are the voltages greater than 11 volts?

Factory service manual diagram





2. CHECK THE LTM (Liftgate/Trunk Module) GROUND CIRCUIT FOR AN OPEN

1. Ignition OFF.

2. Measure:

Factory service manual diagram



Factory service manual diagram




Is the resistance less than 3 ohms?

Factory service manual diagram





3. CHECK THE MS-CAN (Medium Speed Controller Area Network) CIRCUITS BETWEEN THE LTM (Liftgate/Trunk Module) AND THE DLC (Data Link Connector) FOR AN OPEN

1. Disconnect: LTM (Liftgate/Trunk Module) C4174B.

2. Measure:

Factory service manual diagram




Are the resistances less than 3 ohms?

Factory service manual diagram





4. CHECK FOR CORRECT LTM (Liftgate/Trunk Module) OPERATION

1. Ignition OFF.

2. Disconnect and inspect the LTM (Liftgate/Trunk Module) connectors.

3. Repair:

- corrosion (replace connector or terminals- clean module pins)
- damaged or bent pins- replace terminals/pins
- pushed-out pins- replace pins as necessary

4. Reconnect the LTM (Liftgate/Trunk Module) connectors. Make sure they seat and latch correctly.

5. Operate the system and verify the concern is still present.

Is the concern still present?

Factory service manual diagram




Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.