2012 Ford Explorer AWD V6-3.5LFACTORY OEM SERVICE PROCEDURE

Diagnostic Routine J




Diagnostic Routine J

Diagnostic Overview

The Heating Ventilation Air Conditioning (HVAC) Module Does Not Respond To The Scan Tool

Refer to Wiring Diagram Set 14 for schematic and connector information Electrical Diagrams.

Refer to Wiring Diagram Set 54 for schematic and connector information Electrical Diagrams.

Refer to Wiring Diagram Set 55 for schematic and connector information Electrical Diagrams.

Normal Operation and Fault Conditions

The HVAC (Heating, Ventilation, and Air Conditioning) module communicates with the scan tool through the MS-CAN (Medium Speed Controller Area Network).

Visual Inspection and Diagnostic Pre-checks

Verify BCM (Body Control Module) fuse 46 (10A) is OK.

Pinpoint Test

1. CHECK THE MS-CAN (Medium Speed Controller Area Network) TERMINATION RESISTANCE

1. Ignition OFF.

2. Measure:

Factory service manual diagram




Is the resistance between 54 and 66 ohms?

Factory service manual diagram





2. CHECK THE MS-CAN (Medium Speed Controller Area Network) TERMINATION RESISTANCE WITH THE HVAC (Heating, Ventilation, and Air Conditioning) MODULE DISCONNECTED

1. Disconnect: HVAC (Heating, Ventilation, and Air Conditioning) Module C228A.

2. Measure:

Factory service manual diagram




Is the resistance between 108 and 132 ohms?

Factory service manual diagram





3. CHECK THE HVAC (Heating, Ventilation, and Air Conditioning) MODULE VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

1. Disconnect: HVAC (Heating, Ventilation, and Air Conditioning) Module C228A.

2. Ignition ON.

3. Measure:

Factory service manual diagram




Is the voltage greater than 11 volts?

Factory service manual diagram





4. CHECK THE HVAC (Heating, Ventilation, and Air Conditioning) MODULE GROUND CIRCUIT FOR AN OPEN

1. Ignition OFF.

2. Measure:

Factory service manual diagram




Is the resistance less than 3 ohms?

Factory service manual diagram





5. CHECK THE MS-CAN (Medium Speed Controller Area Network) CIRCUITS BETWEEN THE HVAC (Heating, Ventilation, and Air Conditioning) MODULE AND THE DLC (Data Link Connector) FOR AN OPEN

1. Measure:

Factory service manual diagram




Are the resistances less than 3 ohms?

Factory service manual diagram





6. CHECK THE MS-CAN (Medium Speed Controller Area Network) CIRCUITS FOR A SHORT TO POWER

1. Connect: HVAC (Heating, Ventilation, and Air Conditioning) Module C228A.

2. Ignition ON.

3. Measure:

Factory service manual diagram




Factory service manual diagram




Is the voltage greater than 3 volts on either circuit?

Factory service manual diagram





7. CHECK THE MS-CAN (Medium Speed Controller Area Network) CIRCUITS FOR A SHORT TO GROUND

1. Ignition OFF.

2. Measure:

Factory service manual diagram




Are the resistances greater than 10,000 ohms?

Factory service manual diagram





8. CHECK FOR CORRECT HVAC (Heating, Ventilation, and Air Conditioning) MODULE OPERATION

1. Ignition OFF.

2. Disconnect and inspect the HVAC (Heating, Ventilation, and Air Conditioning) module connectors.

3. Repair:

- corrosion (replace connector or terminals- clean module pins)
- damaged or bent pins- replace terminals/pins
- pushed-out pins- replace pins as necessary

4. Reconnect the HVAC (Heating, Ventilation, and Air Conditioning) module connectors. Make sure they seat and latch correctly.

5. Operate the system and verify the concern is still present.

Is the concern still present?

Factory service manual diagram




Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.