2009 Ford Focus L4-2.0LFACTORY OEM SERVICE PROCEDURE

Compressor HVAC: Testing and Inspection




A/C Compressor - External Leak Test

1. Install the appropriate adapter from the A/C Flush Adapter Test on the port of the A/C compressor, using the existing manifold retaining bolt.

2. Connect the high and low pressure lines of a manifold gauge set or a refrigerant recovery/recycling station to the corresponding fittings on the adapter.

3. Attach the center hose of a manifold gauge set to a refrigerant container standing in an upright position.

4. Open the low-pressure gauge valve, the high-pressure gauge valve and the valve on the refrigerant container to allow the refrigerant vapor to flow into the A/C compressor.

5. Using the Refrigerant Leak Detector, check for leaks at the compressor shaft.

6. If a shaft seal or external leak is found, install a new A/C compressor.

7. When the leak test is complete, recover the refrigerant from the compressor.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.