Line Pressure Chart
LINE PRESSURE CHART
| Application | Range | Idle | WOT | ||
|---|---|---|---|---|---|
| EPC | Line Pressure | EPC | Line Pressure | ||
| All | P, N | 34-276 kPa (5-40 psi) | 276-689 kPa (40-100 psi) | N/A | N/A |
| Β | OD, 2, 1 | 34-276 kPa (5-40 psi) | 276-689 kPa (40-100 psi) | 689-793 kPa (100-115 psi) | 1,172-1,586 kPa (170-230 psi) |
| Β | R | 172-207 kPa (25-30 psi) | 483-862 kPa (70-125 psi) | 586-655 kPa (85-95 psi) | 1,124-2,068 kPa (250-300 psi) |