Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2005 Ford Freestar BaseFACTORY OEM SERVICE PROCEDURE
Smart Junction Box (SJB)
SMART JUNCTION BOX DIAGNOSTIC TROUBLE CODE (DTC) LIST
| DTC | Description | Perform Test |
|---|---|---|
| C1779 | (Single-zone EMTC only) Blower request signal circuit short to ground | GO to PINPOINT TEST L . |
| B2175 | (Single-zone EMTC only) A/C request signal circuit short to ground | GO to PINPOINT TEST I . |
| B2513 | Blower motor relay circuit short to ground | EMTC and blower is inoperative, GO to PINPOINT TEST K
. EMTC and blower operates, GO to PINPOINT TEST L
. EATC and blower is inoperative, GO to PINPOINT TEST M . EATC and blower operates, GO to PINPOINT TEST N . |
| B2514 | Blower motor relay circuit open/short to voltage | EMTC, GO to PINPOINT TEST K
. EATC, GO to PINPOINT TEST M . |
| B2543 | Auxiliary control/actuator reference circuit short to ground | If auxiliary blower, temperature and mode are all affected, GO to PINPOINT TEST O
. If temperature only is affected, GO to PINPOINT TEST Q . If mode only is affected, GO to PINPOINT TEST R . |
| B2544 | Auxiliary control/actuator reference circuit short to voltage | If auxiliary blower, temperature and mode are all affected, GO to PINPOINT TEST P
. If temperature only is affected, GO to PINPOINT TEST Q . If mode only is affected, GO to PINPOINT TEST R . |
| B2559 | Auxiliary blower motor relay circuit short to voltage | GO to PINPOINT TEST O . |
| B2688 | Auxiliary blower motor relay circuit open/short to ground | If auxiliary blower motor is inoperative, GO to PINPOINT TEST O
. If auxiliary blower motor operates, GO to PINPOINT TEST P . |
| B2561 | Auxiliary blower motor speed relay 1 circuit short to voltage | GO to PINPOINT TEST P . |
| B2562 | Auxiliary blower motor speed relay 1 circuit open/short to ground | GO to PINPOINT TEST P . |
| B2563 | Auxiliary blower motor speed relay 2 circuit short to voltage | GO to PINPOINT TEST P . |
| B2564 | Auxiliary blower motor speed relay 2 circuit open/short to ground | GO to PINPOINT TEST P . |
| B2916 | Auxiliary blend door motor circuits shorted | GO to PINPOINT TEST Q . |
| B2917 | Auxiliary mode door motor circuits shorted | GO to PINPOINT TEST R . |
| B2919 | Auxiliary blower motor speed input circuit short to voltage | GO to PINPOINT TEST P . |
| B2920 | Auxiliary mode door feedback circuit open/shorted | GO to PINPOINT TEST R . |
| B2921 | Auxiliary blend door feedback circuit open/shorted | GO to PINPOINT TEST Q . |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.