Test X: Constant Control Relay Module: Testing
- 1) Check For Open VPWR Circuit Between IAC Valve & CCRM
Turn ignition switch to OFF position. Disconnect fuel injector and CCRM connectors. See CCRM LOCATIONS table. Disconnect scan tool from Data Link Connector (DLC). Using a DVOM, measure resistance of VPWR circuit between fuel injector harness connector and CCRM harness connector terminals No. 12 and 24. See Figure-Figure . If both resistances are less than 5 ohms, reconnect fuel injector and go to next step. If both resistances are 5 ohms or more, repair open in VPWR circuit between CCRM and splice to fuel injector. See WIRING DIAGRAMS . - 2) Check B+ Voltage & IGN START/RUN Voltage To CCRM
Using a DVOM, measure voltage between negative battery terminal and B+ circuit at CCRM harness connector terminals No. 8 and 10. Note voltage. Turn ignition switch to ON position. Using a DVOM, measure voltage between negative battery terminal and IGN START/RUN circuit at CCRM harness connector terminal No. 13. If all voltages are more than 10.5 volts, go to next step. If any voltage measurement is 10.5 volts or less, check related fuses. If fuse is blown, check for short to ground in B+ or IGN START/RUN circuit. Repair as necessary and replace fuse. If fuses are okay, repair open in B+ or IGN START/RUN circuit. - 3) Check CCRM GND Circuit
Turn ignition switch to OFF position. Leave CCRM disconnected. Using a DVOM, measure voltage between terminals No. 8 (VPWR) and No. 15 (GND) at CCRM harness connector. If voltage is more than 10.5 volts, replace CCRM. If voltage is 10.5 volts or less, repair open in GND circuit to CCRM.NOTE: A break in step numbering sequence occurs at this point. Procedure skips from step 3) to step 15). No test procedures have been omitted. - 15) For KOEO & KOER Only DTC P0481 & P1479: Check HFC Control Relay & HFC Circuit In CCRM
DTC P0481 or P1479 is set when PCM detects a High Speed Fan Control (HFC) primary circuit failure. Possible causes are:- Open Or Shorted HFC Circuit
- Open VPWR Circuit To HFC Relay
- Faulty CCRM (HFC Relay Or Internal Circuit)
- Faulty Powertrain Control Module (PCM)
Turn ignition switch to OFF position. Disconnect CCRM connector. See CCRM LOCATIONS table. Using a DVOM, measure HFC relay coil resistance between CCRM terminals No. 17 (HFC) and No. 24 (VPWR). See Figure. Resistance should be 65-110 ohms. Also, measure CCRM internal resistance between terminal No. 17 and terminals No. 1-11, 13 and 21, and CCRM case. Measure resistance of CCRM between terminals No. 15 and 17 (it may be necessary to switch the Red and Black DVOM probes to get resistance reading greater than 1000 ohms). Each resistance should be more than 1000 ohms. If all resistances are as specified, leave CCRM disconnected and go to next step. If any resistance is not as specified, replace CCRM.
- 16) Check For Open In HFC Circuit
Turn ignition switch to OFF position. Disconnect PCM connector. Inspect connector for loose, damaged or corroded terminals. Repair as necessary. Using a DVOM, measure resistance of HFC circuit between CCRM harness connector and PCM harness connector. See Figure-Figure . If resistance is less than 5 ohms, go to next step. If resistance is 5 ohms or more, repair open in HFC circuit. - 17) Check HFC Circuit For Short To PWR In Harness
Turn ignition switch to ON position. Using a DVOM, measure voltage between chassis ground and HFC circuit at PCM harness connector. If voltage is less than one volt, go to next step. If voltage is one volt or more, repair short to PWR in HFC circuit. - 18) Check HFC Circuit For Short To Ground In Harness
Turn ignition switch to OFF position. Disconnect scan tool from Data Link Connector (DLC). Using a DVOM, measure resistance between chassis ground and HFC circuit at PCM harness connector. See Figure-Figure . If resistance is 10 k/ohms or less, repair short to ground in HFC circuit. If resistance is more than 10 k/ohms and DTC P1479 was not retrieved, replace CCRM and verify HIGH FAN PWR circuit is not shorted to ground. If resistance is more than 10 k/ohms and you were directed here to diagnose DTC P0481 or P1479, connect scan tool to DLC. Turn ignition switch to ON position. Using scan tool, access OUTPUT TEST MODE. See OUTPUT TEST MODE under ADDITIONAL SYSTEM FUNCTIONS. Command high speed fan ON, wait 10 seconds and then command high speed fan OFF. If high speed fan turns on and off, disregard DTC P0481 or P1479, repeat QUICK TEST and service any DTCs as necessary. If high speed fan does not turn on and off, replace PCM.NOTE: A break in step numbering sequence occurs at this point. Procedure skips from step 18) to step 20). No test procedures have been omitted. - 20) For KOEO & KOER Only DTC P0480 & P1474: Check Fan Operation
DTC P0480 and P1474 indicate primary circuit failure in Low Fan Control (LFC) circuit or Fan Control (FC) circuit for single cooling fan systems. Possible causes are:- Open Or Shorted FC/LFC Circuit
- Open VPWR Circuit To LFC Relay
- Faulty CCRM (Low Speed Fan Control Relay)
- Faulty PCM
Turn ignition switch to ON position. If cooling fan runs continuously, go to step 24). If cooling fan does not run continuously, go to next step.
- 21) Check FC/LFC Circuit For Short To Ground In Harness
Turn ignition switch to OFF position. Disconnect CCRM connector. Disconnect scan tool from Data Link Connector (DLC). Disconnect PCM connector. Inspect connector for loose, damaged or corroded terminals. Repair as necessary. Using a DVOM, measure resistance between chassis ground and FC/LFC circuit at CCRM harness connector terminal No. 14. See Figure-Figure . If resistance is more than 10 k/ohms, go to next step. If resistance is 10 k/ohms or less, repair FC/LFC circuit for short to ground. - 22) Check Fan Running Mode
Connect CCRM connector. Leave PCM disconnected. Turn ignition switch to ON position. If cooling fan runs continuously, replace PCM. If cooling fan does not run continuously, replace CCRM.NOTE: A break in step numbering sequence occurs at this point. Procedure skips from step 22) to step 24). No test procedures have been omitted. - 24) Check For Open In FC/LFC Circuit In Harness
Turn ignition switch to OFF position. Disconnect CCRM connector. Disconnect PCM connector. Inspect connector for loose, damaged or corroded terminals. Repair as necessary. Using a DVOM, measure resistance of FC/LFC circuit between CCRM harness connector and PCM harness connector. See PCM CONNECTOR IDENTIFICATION and Figure-Figure . If resistance is less than 5 ohms, go to next step. If resistance is 5 ohms or more, repair open in FC/LFC circuit. - 25) Check FC/LFC Circuit For Short To PWR In Harness
Turn ignition switch to ON position. Using a DVOM, measure voltage between chassis ground and FC/LFC circuit at CCRM harness connector terminal No. 14. If voltage is less than one volt, go to next step. If voltage is one volt or more, repair short to B+ Or VPWR in FC/LFC circuit. - 26) FC/LFC Circuit Fault Isolation Check
Turn ignition switch to OFF position. Reconnect CCRM connector. Connect a jumper wire between chassis ground and FC/LFC circuit at PCM harness connector. See PCM CONNECTOR IDENTIFICATION and Figure-Figure . If cooling fan continues to run, replace CCRM. If cooling fan does not continue to run, replace PCM.NOTE: A break in step numbering sequence occurs at this point. Procedure skips from step 26) to step 30). No test procedures have been omitted.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.