2002 Ford ZX2 AutomaticFACTORY OEM SERVICE PROCEDURE

Main Control Valve Body-Assembly: Disassembly

CAUTION: Handle the main control valve body carefully. If any of the components are damaged, it may become the cause of malfunctions in the transmission.
  1. Remove the (A) fluid bypass tube bolts and the (B) fluid bypass tube. Remove the O-rings and seals from the fluid bypass tube and discard them.
    Fig 1: Removing Fluid Bypass Tube
    G01744220Courtesy of FORD MOTOR CO.
  2. Remove the electrical solenoids.
    1. Remove the bolts.
    2. Remove the torque converter clutch (TCC) solenoid.
    3. Remove the 1-2 shift solenoid.
    Fig 2: Removing Solenoids
    G01744221Courtesy of FORD MOTOR CO.
  3. Remove the 2-3 shift solenoid and the 3-4 shift solenoid.
    1. Remove the 2-3 shift solenoid bolt.
    2. Remove the 3-4 shift solenoid bolt.
    3. Remove the 2-3 shift solenoid and the 3-4 shift solenoid.
    4. Remove the shift solenoid wiring harness bolt.
    Fig 3: Removing 2-3 Shift Solenoid & 3-4 Shift Solenoid
    G01744222Courtesy of FORD MOTOR CO.
  4. NOTE: Loosen the upper control valve body bolts evenly and gradually.
  5. Remove the (A) upper control valve body bolts and the (B) upper control valve body.
  6. Fig 4: Removing Upper Control Valve Body Bolts & Upper Control Valve Body
    G01744223Courtesy of FORD MOTOR CO.
  7. Remove the (A) screw securing the main upper gasket, the upper separator plate, and the upper gasket to the upper control valve body.
  8. Fig 5: Removing Screw Securing Main Upper Gasket, Upper Separator Plate & Upper Gasket To Upper Control Valve Body
    G01744224Courtesy of FORD MOTOR CO.
  9. Remove the jet orifice and nut from the upper separator plate.
    Fig 6: Removing Jet Orifice & Nut From Upper Separator Plate
    G01744225Courtesy of FORD MOTOR CO.
  10. Remove the (A) upper gasket, (B) upper separator plate, (C) filter, and the (D) main upper gasket.
  11. Fig 7: Removing Upper Gasket, Upper Separator Plate, Filter, & Main Upper Gasket
    G01744226Courtesy of FORD MOTOR CO.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.