2002 Ford ThunderbirdFACTORY OEM SERVICE PROCEDURE

Test C: System Overcharges

  1. Connect New Generation Star (NGS) tester to Data Link Connector (DLC). Turn ignition on. Using NGS tester, perform Powertrain Control Module (PCM) self-test. If no DTCs are retrieved, go to next step. If any Diagnostic Trouble Codes (DTC) are retrieved, perform appropriate test in accordance with DTC retrieved. See DIAGNOSTIC TROUBLE CODE DEFINITIONS in SELF-DIAGNOSTICS article in ENGINE PERFORMANCE.
  2. Turn ignition off. Reconnect generator 3-pin harness connector. Start engine. Check generator output. See GENERATOR LOAD TEST  under ON-VEHICLE TESTING. If generator tests okay, go to next step. If generator does not test okay, replace generator. See GENERATOR  under REMOVAL & INSTALLATION.
  3. Turn ignition off. Disconnect generator 3-pin harness connector. Turn ignition on. Measure voltage between ground and generator harness connector terminal No. 3 (Red wire). See Figure. If voltage is less than .5 volt from battery voltage, replace generator. See GENERATOR  under REMOVAL & INSTALLATION. If voltage is greater than .5 volt from battery voltage, repair high resistance in Red wire. See WIRING DIAGRAMS .
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.