2002 Ford Taurus SES, 3.0 U, AX4SFACTORY OEM SERVICE PROCEDURE

Test B: Generic Electronic Module Does Not Respond To Scan Tool

WARNING: This page is about a different car, the 2002 Ford Mustang. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Perform all voltage and resistance tests using a Digital Volt-Ohm Meter (DVOM) with a minimum 10-megohm input impedance, unless stated otherwise in test procedure. Use ohmmeter to isolate wiring harness shorts or opens.
  1. Turn ignition switch to LOCK position. Disconnect Generic Electronic Module (GEM) 26-pin harness connector C352. See Fig 1. GEM is located behind left side of instrument panel, next to central junction box. See Figure. Inspect connector for loose, damaged or corroded terminals. If connector terminals are faulty, repair or replace as necessary. If connector terminals are okay, go to next step.
  2. Measure resistance between GEM harness connector C201e terminal No. 6 and DLC terminal No. 7 (Light Blue/White wire). See Figure and Fig 1 . If resistance is 5 ohms or less, replace GEM. See GENERIC ELECTRONIC MODULEΒ  under REMOVAL & INSTALLATION. If resistance is more than 5 ohms, repair open circuit in Light Blue/White wire between GEM and DLC. For DATA LINK CONNECTOR circuit identification, see WIRING DIAGRAMSΒ .
Fig 1: Identifying Generic Electronic Module Harness Connector C201e Terminals
G99F02718Courtesy of FORD MOTOR CO.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.