2002 Ford Crown Victoria Base, 4.6 9FACTORY OEM SERVICE PROCEDURE

Master Power Window Switch

  1. Remove master power window switch. See POWER WINDOW SWITCHΒ  under REMOVAL & INSTALLATION. With all switches in NEUTRAL position and lock-out switch in OFF position, continuity should exist between terminals No. 19 and 20. See Fig 1. Continuity should also exist between terminal No. 13 and all other terminals except terminal No. 19. If continuity is as specified, go to next step. If continuity is not as specified, replace master power window switch.
  2. Check continuity between specified switch terminals with switch in appropriate position. See MASTER POWER WINDOW SWITCH TESTΒ  table. If continuity is not as specified, replace master power window switch.
MASTER POWER WINDOW SWITCH TEST

Switch Position Continuity Between Terminals No.
Left Front Window
Down 8 & 13; 10 & 19
Up 8 & 19; 10 & 13
Left Rear Window
Down 13 & 17; 15 & 19
Up 13 & 15; 17 & 19
Right Front Window
Down 9 & 13; 11 & 19
Up 9 & 19; 11 & 13
Right Rear Window
Down 13 & 18; 16 & 19
Up 13 & 16; 18 & 19
Fig 1: Identifying Master Power Window Switch Terminals (Component Side)
G99B02194Courtesy of FORD MOTOR CO.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.