2000 Ford Contour SVTFACTORY OEM SERVICE PROCEDURE

Generator Specifications

WARNING: This page is about a different car, the 2002 Lincoln Navigator, 2002 Lincoln Blackwood, 2002 Ford Pickup, and 2002 Ford Expedition. However, it is still accessible from the selected car via links, so may be relevant.
GENERATOR SPECIFICATIONS

Application Specification
Blackwood, Expedition & Navigator
Generator Amperage Rating
4.6L & 5.4L 2V 110 Amp
5.4L 4V 115 Amp
Load Test (1)
With Tester Load (2) 87 Amps Or More
Without Tester Load (3) (4)
No-Load Test (1)(2) 13-15 Volts
F150
Generator Amperage Rating
4.2L, 4.6L & 5.4L 110 Amp
Lightning 5.4L SC 120 Amp
Load Test (1)
With Tester Load (2) 58 Amps Or More
Without Tester Load (3) (4)
No-Load Test (1)(2) 13-15 Volts
(1) All tests are performed with engine running at 2000 RPM.
(2) All accessories off.
(3) Perform this test with engine running, A/C on, blower motor on high speed, and headlamps on high beam.
(4) With accessories on, voltage should increase a minimum of 0.5 volt above base voltage.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.