2000 Ford Contour SVTFACTORY OEM SERVICE PROCEDURE

Test E: Charge System Indicator Flickers Or Operates Intermittently

  1. Turn ignition switch to OFF position. Measure voltage between generator terminal "F" and ground. See Figure . If battery voltage is present, go to next step. If battery voltage is not present, go to step  3 .
  2. Start engine. Connect jumper wire between generator terminal "A" and battery positive terminal. See Figure . Observe charge warning indicator. If indicator flickers, replace voltage regulator. See VOLTAGE REGULATOR  under REMOVAL & INSTALLATION. Retest system operation. If indicator does not flicker, repair Black wire or connections between generator and battery. See WIRING DIAGRAMS  . Retest system operation.
  3. Remove generator. See GENERATOR  under REMOVAL & INSTALLATION. Inspect brush holder screws (generator terminals "A" and "F"). See Figure . If screws are okay, go to next step. If screws are loose, clean and tighten screws to 26 INCH lbs. (3 N.m). Retest system operation.
  4. Remove voltage regulator. See VOLTAGE REGULATOR  under REMOVAL & INSTALLATION. Measure resistance between each generator slip ring and ground. See Fig 1 . If resistance is 200 ohms or greater, replace voltage regulator. If resistance is less than 200 ohms, clean accumulated grease or dirt from around slip rings and recheck resistance. If resistance is still less than 200 ohms, replace generator. See GENERATOR  under REMOVAL & INSTALLATION.
    Fig 1: Checking For Grounded Generator Slip Ring
    G00013627Courtesy of FORD MOTOR CO.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.