1999 Ford Taurus SHOFACTORY OEM SERVICE PROCEDURE

Test C

  1. Disconnect generator 3-pin connector. Measure voltage between connector terminal "A" (Orange/Light Blue wire) and ground. If battery voltage is present, go to next step. If battery voltage is not present, check battery junction box fuse No. 26 (30-amp). Replace fuse as necessary. If fuse is okay, repair open in Orange/Light Blue wire. See WIRING DIAGRAMS . Check system operation.
  2. Leave generator 3-pin connector disconnected. Observe charge warning indicator with ignition on, engine off. If indicator does not illuminate, go to next step. If indicator illuminates, repair short to ground in Light Green/Red wire. See WIRING DIAGRAMS . Check system operation.
  3. Restore connections and turn off all accessories. Start engine and run at 2000 RPM. Measure voltage between generator terminal B+ (Yellow/White wire) and ground. If voltage is greater than 15.5 volts, go to TEST B . If voltage is 15.5 volts or less, replace voltage regulator and check system operation. See VOLTAGE REGULATOR  under REMOVAL & INSTALLATION.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.