1999 Ford Contour SVTFACTORY OEM SERVICE PROCEDURE

Leak Test

NOTE: After vehicle has sat for several hours, a very slight natural gas smell may emanate from within intake manifold and intake air system. This is a normal condition. After several hours, fuel injectors leak down.

  1. Fuel Rail & Fuel Injectors

    Turn ignition off. Remove Fuel Shutoff Valve (FSV) relay from power distribution box in engine compartment. To pressurize fuel system, connect a jumper wire between FSV relay socket No. 87 and 30. See Fig 1-Fig 3 . Remove jumper wire and reinstall FSV relay.
    NOTE: To identify Fuel Shutoff Valve (FSV) relay terminals, refer to numbers molded on relay. FSV relay is also referred to as fuel valve relay.
  2. Using leak detector provided with Natural Gas Vehicle (NGV) Pressure Test and Vent Kit (134-00114), check for leakage at spring lock coupling and fuel rail-to-fuel injector connections. If a leak is detected, repair as necessary and retest.
Fig 1: Connecting Jumper Wire To Fuel Shutoff Valve Relay Connector (Crown Victoria)
G99D02864
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.