Test G: One-Touch Down Feature Does Not Operate
NOTE:
This test is associated with DTCs B1398, B1400 and B1342.
- Check Ignition States - Turn ignition off. Using NGS tester, access GEM PID IGN_GEM. Monitor GEM PID IGN_GEM PID while rotating ignition switch through START, RUN, OFF and ACC positions. If GEM PID IGN_GEM values agree with ignition switch positions, go to next step. If GEM PID IGN_GEM values do not agree with ignition switch positions, repair or replace ignition switch and retest system operation.
- Retrieve DTCs - Using NGS tester, retrieve and record continuous DTCs. Clear continuous DTCs and perform GEM On-Demand Self-Test. If no DTCs are retrieved, go to next step. If DTCs B1398 and/or B1400 are retrieved, go to next step. If DTC B1342 is present, replace GEM. Clear DTCs and retest system operation.
- Check One-Touch Down Relay Coil Circuit - Turn ignition switch to RUN position. Using NGS tester, access GEM active command ACCY RLY. Trigger GEM active command mode ACCY RLY on. Monitor GEM PID D_PWRLY while triggering active command ONE TOUCH on and off. If GEM PID D_PWRLY value agrees with command mode, go to step 9). If NGS tester indicates OFFO-G, go to next step. If NGS tester indicates ON-B-, go to step 7).
- Check One-Touch Down Relay - Turn ignition off. Check one-touch down relay. See BATTERY SAVER & ONE-TOUCH DOWN RELAY under COMPONENT TESTS. If one-touch down relay is okay, go to next step. If one-touch down relay does not test as specified, replace one-touch down relay. Clear DTCs and retest system operation.
- Check Light Blue/Black Wire For Open - Turn ignition off. Remove accessory delay relay and one-touch down relay from relay module located behind center of instrument panel. Using an ohmmeter, check resistance in Light Blue/Black wire between accessory delay relay connector terminal No. 30 and one-touch down relay connector terminal No. 2. See Figure and Figure . If resistance is less than 5 ohms, go to next step. If resistance is 5 ohms or more, repair open in Light Blue/Black wire. Clear DTCs and retest system operation.
- Check Yellow/Red Wire For Open - Disconnect 18-pin GEM connector C283 (located behind center of instrument panel). Using an ohmmeter, check resistance in Yellow/Red wire between one-touch down relay connector terminal No. 1 and 18-pin GEM connector C283 terminal No. 7. See Figure and Figure . If resistance is less than 5 ohms, replace GEM. Clear DTCs and retest system operation. If resistance is 5 ohms or more, repair open in Yellow/Red wire. Clear DTCs and retest system operation.
- Check One-Touch Down Relay - Turn ignition off. Check one-touch down relay. See BATTERY SAVER & ONE-TOUCH DOWN RELAY under COMPONENT TESTS. If one-touch down relay is okay, go to next step. If one-touch down relay does not test as specified, replace one-touch down relay. Clear DTCs and retest system operation.
- Check Yellow/Red Wire For Short To Power - Turn ignition off. Disconnect 18-pin GEM connector C283 (located behind center of instrument panel). Turn ignition switch to RUN position. Using a voltmeter, check voltage between ground and one-touch down relay connector terminal No. 1 (Yellow/Red wire). If any voltage is present, repair short to power in Yellow/Red wire. Clear DTCs and retest system operation. If no voltage is present, replace GEM. Clear DTCs and retest system operation.
- Check One-Touch Down Relay - Turn ignition off. Check one-touch down relay. See BATTERY SAVER & ONE-TOUCH DOWN RELAY under COMPONENT TESTS. If one-touch down relay is okay, go to next step. If one-touch down relay does not test as specified, replace one-touch down relay. Clear DTCs and retest system operation.
- Check Voltage To Switch Side Of One-Touch Down Relay - Turn ignition off. Remove one-touch down relay (located in relay module, behind center of instrument panel). Turn ignition switch to RUN position. Using a voltmeter, check voltage between ground and one-touch down relay connector terminal No. 2 (Light Blue/Black wire). Check voltage between ground and one-touch down relay connector terminal No. 5 (Light Blue/Black wire). If both voltage readings are more than 10 volts, go to next step. If either voltage reading is 10 volts or less, repair appropriate Light Blue/Black wire. Clear DTCs and retest system operation.
- Check Gray Wire For Open - Disconnect 18-pin GEM connector C283 (located behind center of instrument panel). Disconnect driver door power window motor connector C504. See POWER WINDOW MOTOR R & I under REMOVAL & INSTALLATION. Using an ohmmeter, check resistance between 18-pin GEM/CTM connector C283 terminal No. 10 (Gray wire) and driver door power window motor connector C504 Red wire terminal. If resistance is less than 5 ohms, go to next step. If resistance is 5 ohms or more, repair open in Gray wire. Clear DTCs and retest system operation.
- Check Orange/White Wire For Open - Using an ohmmeter, check resistance between 18-pin GEM connector C283 terminal No. 2 (Orange/White wire) and driver door power window motor connector C504 Red wire terminal. If resistance is less than 5 ohms, replace GEM. Clear DTCs and retest system operation. If resistance is 5 ohms or more, repair open in Orange/White wire. Clear DTCs and retest system operation.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.