Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1996 Ford Probe Base, AutomaticFACTORY OEM SERVICE PROCEDURE
Both Power Windows Inoperative
- Check POWER WINDOW (30-amp) fuse. Replace fuse if blown. If fuse blows after replacing, go to next step. If fuse does not blow, go to step 4).
- Turn ignition off. Disconnect 16-pin interior fuse panel connector. See Fig 1 . Disconnect master switch connector and right switch (passenger side) connector. Measure resistance between Black/Red wire terminal of 16-pin interior fuse panel connector and ground. If resistance is less than 10 k/ohms, repair shot to ground in Black/Red wire between power window switches and interior fuse panel. If resistance is greater than 10 k/ohms, go to next step.
- With ignition off, disconnect master switch connector. Measure resistance between ground and following connector terminals: Green/Blue wire, Red/Blue wire, Green/White wire and Red/White wire. If any resistance is less than 10 k/ohms, repair circuit in question for a short to ground. If all resistance measurements are greater than 10 k/ohms, reconnect interior fuse panel and go to next step.
- With ignition off, disconnect master switch connector. Turn ignition on. Measure voltage at Black/Red wire terminal of master switch connector. If voltage is more than 10 volts, go to next step. If voltage is less than 10 volts, repair Black/Red wire between switch and interior fuse panel.
- With ignition off, remove METER (15-amp) fuse from fuse panel. Disconnect master switch connector. Measure resistance of Black wire between master switch connector and ground. If resistance is more than 5 ohms, repair Black wire. If resistance is less than 5 ohms, replace master switch.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.