1996 Ford Probe Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Pinpoint Test A - Door Lock System Does Not Operate

NOTE: In following pinpoint tests, illustrations are courtesy of Ford Motor Co.
  1. Turn ignition off. Inspect ROOM and METER fuses at interior fuse box. If fuses are okay, go to step 4). If either fuse is defective, go to next step.
  2. Install new fuses. Turn ignition on. If fuses fail again, go to next step. If fuses are okay, go to step 4).
  3. Turn ignition off. Unplug REM connector and interior fuse panel connector C2. See Fig 1 . Measure resistance between Blue/Red wire at interior fuse panel C2 connector and ground. Measure resistance between Black/Yellow wire at interior fuse panel C2 connector and ground. If resistances are less than 5 ohms, repair wire(s) in question. If resistances are greater than 5 ohms, replace fuse(s), then go to next step.
    Fig 1: Locating Remote Keyless Entry Components (Probe)
    G96E01134
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.