1995 Ford Contour SE, StandardFACTORY OEM SERVICE PROCEDURE

Ignition Switch

  1. Check for continuity between specified terminals with ignition switch in each position. See Fig 1 . If continuity is not as specified, or is poor in any switch position, replace ignition switch.
    Fig 1: Identifying Ignition Switch Terminals
    G95G12506Courtesy of FORD MOTOR CO.
  2. Continuity should exist between terminals 2 and 6 with ignition switch in START position only (starter relay circuit). Continuity should not exist in all other switch positions.
  3. Continuity should exist between terminals 4 and 10 with ignition switch in START position only (start power circuit). Continuity should not exist in all other switch positions.
  4. Continuity should exist between terminals 2 and 5 with ignition switch in RUN position only. Continuity should not exist in all other switch positions.
  5. Continuity should exist between terminals 2 and 9 with ignition switch in ACC position only. Continuity should not exist in all other switch positions.
  6. Continuity should exist between terminals 2 and 7 with key inserted in ignition switch (key reminder circuit). Continuity should not exist when key is not inserted.
Chapter Navigation
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.