1993 Ford Probe Base, AutomaticFACTORY OEM SERVICE PROCEDURE
Motor Relay Operation Check
- Turn ignition off. Disconnect ABS control module. Turn ignition on. At ABS control module, connect Blue/Black wire to ground. Connect Blue/Orange wire to ground for no longer than 2 SECONDS. See Figure .
- If motor relay clicks and motor operates when Blue/Black wire is momentarily grounded, go to PINPOINT TEST MMR-10Β . If motor relay clicks, but motor does not operate, go to PINPOINT TEST MMR-7Β . If motor relay does not click and motor does not operate, go to PINPOINT TEST MMR-4Β .
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.