1993 Ford Explorer 2D Utility, RWD, AutomaticFACTORY OEM SERVICE PROCEDURE

Aerostar (Multiple Switch)

Testing of the power window multiple switch should be performed with the switch removed from the vehicle. Use a self-powered test lamp or an ohmmeter such as Rotunda Digital Volt-Ohmmeter (007-00001), or equivalent.

  1. Clip one test lead probe on terminal No. 6 which is grounded. With both switches in the neutral position, terminals No. 1 through 4 should have continuity to terminal No. 6.See Fig 1 .
  2. Push both window switches upward (toward window when in installed position). Both terminals No. 1 and 3 should have no continuity to terminal No. 6. Push both window switches downward (away from window when in installed position). Both terminals No. 2 and 4 should have no continuity to terminal No. 6.
  3. Remove the test lead from terminal No. 6 and connect to terminal No. 5 (hot feed terminal). With both switches in the neutral position, terminal No. 5 should have continuity only with itself. Push both window switches upward (toward the window when in installed position). Both terminals No. 1 and 3 should have continuity to terminal No. 5.
  4. Push both window switches downward (away from the window when in installed position). Both terminals No. 2 and 4 should have continuity to terminal No. 5. If any one switch does not test as stated, replace the complete switch assembly. See WINDOW SWITCHΒ  under REMOVAL & INSTALLATION.
Fig 1: Testing Power Window Switch (Multiple Switch, Aerostar)
G00088814Courtesy of FORD MOTOR CO.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.