1991 Ford Probe LX, AutomaticFACTORY OEM SERVICE PROCEDURE

Coil Test

  1. Attach negative (-) VOM lead to distributor base and measure battery voltage. Turn ignition switch to RUN position. Measure voltage at coil positive (+) terminal of ignition coil and turn ignition off. Voltage should be 10.5-12 volts. If voltage is as specified, go to next step. If voltage is not as specified, repair ignition switch or wiring circuit to coil. See appropriate wiring diagram unde rWIRING DIAGRAMSΒ  .
  2. Ensure ignition is off. Disconnect coil primary connector and inspect both contacts for corrosion or damage. Service or replace as necessary. Using a DVOM, measure primary circuit resistance. If resistance is not 0.3-1.0 ohm at 70Β°F, replace coil and retest system.
  3. Remove secondary coil wire from coil tower and inspect contact for signs of arcing or corrosion. Using a DVOM, measure resistance between coil tower connector and coil negative (-) terminal. If resistance is not 8000-11,500 ohms, replace coil.