1991 Ford Probe GL, StandardFACTORY OEM SERVICE PROCEDURE
Pressure Switch Check
- Start engine. Disconnect pressure switch hose and apply 10.5-11.5 psi (.72-.80 kg/cm2 ) compressed air to switch. Engine should stall or run poorly with air pressure applied. If engine does not function as described, turn ignition off.
- Disconnect pressure switch connector. Turn ignition on. Using a voltmeter, apply positive lead to Light Green/Black wire and negative lead to ground. Voltage should be 10 volts with 10.5-11.5 psi (.72-.80 kg/cm2 ) applied, and zero volt with no air pressure applied.
- If pressure is not as specified, turn ignition off. With 10.5-11.5 psi (.72-.80 kg/cm2 ) applied, check continuity between switch terminals. Continuity should be present with 10.5-11.5 psi (.72-.80 kg/cm2 ) applied. Continuity should not be present when no air pressure is applied.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.