AFR-5 Signal At Abs Control Unit

1991 Ford Probe GL, StandardSECTION AFR-5 Signal At Abs Control Unit

Ensure ignition is off. Set voltmeter to 5V AC scale. Measure voltage between ABS control unit terminal 2C (Yellow wire) and terminal 2D (Orange wire) while rotating right front wheel 60 RPM. Voltage should be greater than 0.25 volt AC. If correct, go to AFR-7 ABS CONTROL UNIT CHECK  . If not correct, go to AFR-6 SENSOR SET-UP CHECK  .