1991 Ford Probe GL, StandardFACTORY OEM SERVICE PROCEDURE

P-3 Check Abs Control Unit

Disconnect hydraulic control unit. Turn ignition on. Measure voltage at ABS control unit Yellow/White, Yellow/Red, Yellow/Green, Blue, Black/White and Brown terminals. If voltage is greater than 10 volts, replace ABS control unit. If voltage is less than 10 volts, replace hydraulic control unit.