1991 Ford Probe GL, AutomaticFACTORY OEM SERVICE PROCEDURE

Stator Windings Open Test

NOTE: To perform the following test, disassembly of the alternator is required. The rectifier assembly must be disconnected from the stator prior to performing tests to either unit.

Remove stator from alternator. Set ohmmeter on "x1" scale. Connect one ohmmeter probe to stator lead and other probe to another stator lead. If no meter movement occurs, stator coil is open and must be replaced. Repeat test with other stator leads. DO NOT touch probes or stator leads, or an incorrect reading will result.

Chapter Navigation
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.