1991 Ford Probe GL, AutomaticFACTORY OEM SERVICE PROCEDURE

Ca-4 Abs Output Check

Disconnect only Black wire from hydraulic unit. Start engine. Set voltmeter to 20V scale. Measure voltage between ABS control unit Blue/Orange wire and ground when the following ABS control unit terminals are grounded with jumper wire.

ABS OUTPUT CHECK

Terminal No. Volts
2K (Blue/Black wire) & 2I (Green/Red wire) Greater than 10
2I (Green/Red wire) Only Less than 2
2K (Blue/Black wire) Only Greater than 10
Neither terminal Greater than 10

If output is correct, go to CA-5 PUMP OPERATION CHECKΒ  . If output is not correct, replace ABS control unit.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.