1990 Ford Probe L4-133 2.2L SOHCFACTORY OEM SERVICE PROCEDURE
Ignition Timing: Adjustments
1 Warm up the engine to the normal operating temperature.
2 Turn all electrical loads OFF.
3 Connect a tachometer and timing light.
Test Connector:
4 Connect a jumper wire between the black one pin STI connector and ground.
5 Check the idle speed and adjust to specifications (750 +/- 25 RPM).
Timing Marker:
6 Check to make sure the yellow timing mark on the crankshaft pulley and the mark on the timing belt cover line up.
NOTE: On Turbo models Specification is 9° +/- 1° BTDC. On Non-Turbo models Specification is 6° +/- 1° BTDC with the vacuum hoses disconnected and plugged.
Distributor Rotation:
Distributor Rotation:
7 If the marks do not line up, loosen the distributor lock bolt and turn the distributor housing to make the adjustment.
8 Reconnect the vacuum hoses and disconnect the jumper wire to the STI connector.
9 Tighten the distributor lock bolt to specification 14-19 lb-ft (19-25 Nm).
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.