Test H: Step 17

17) Check HEGO Sensor For Short to Ground  With key off, breakout box installed, and ECA disconnected, set DVOM to 200-k/ohm scale. Disconnect HEGO sensor. Measure resistance between PWR GND and HEGO SIGNAL at the HEGO sensor connector. On trucks with 4-wire sensors, measure resistance between PWR GND, HEGO GND and HEGO SIG at the HEGO sensor connector. If resistance is less than 10 k/ohms, replace HEGO sensor, remove breakout box, reconnect all components and repeat QUICK TEST. If resistance is greater than 10 k/ohms, go to the appropriate following procedure.

  • Engines equipped with MAP sensor: Go to next step.
  • Engines equipped with MA (Mass Air Sensor): Remove breakout box, reconnect HEGO sensor, replace ECA and rerun QUICK TEST.
Fig 1: Checking HEGO Sensor
G90A12443
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.