1990 Ford Bronco II RWD, Standard, M5OD-R1FACTORY OEM SERVICE PROCEDURE

Test H: Step 16

16) Check HEGO Circuit For Short to Ground  Turn key off. Leave breakout box installed and ECA disconnected. Disconnect HEGO sensor and set DVOM on 200-k/ohm scale. Measure resistance between test pin No. 29 and test pins No. 40 and 49 at the breakout box. For trucks equipped with 4-wire sensors, measure resistance between test pin No. 29 and test pins No. 40 and 46 at the breakout box. For vehicles with dual sensors, measure resistance between test pin No. 43 and test pin No. 40. If any reading is less than 10 k/ohms, repair short to ground. Remove breakout box, reconnect all components and repeat QUICK TEST. If reading is 10 k/ohms or more, go to next step.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.