1990 Ford Bronco II RWD, Standard, M5OD-R1FACTORY OEM SERVICE PROCEDURE

7.5L Engine

  1. Rotate crankshaft until No. 1 piston is at TDC. Use Lifter Bleed Down Wrench (T70P-6513-A) to bleed down each lifter until the plunger bottoms. Valve clearance is .075-.175" (1.9-4.4 mm). In this position, check the following valves:
    • No. 1 Intake and No. 1 Exhaust
    • No. 3 Intake and No. 4 Exhaust
    • No. 7 Intake and No. 5 Exhaust
    • No. 8 Intake and No. 8 Exhaust
  2. Rotate crankshaft 360 degrees in direction of rotation and check the following valves:
    • No. 2 Intake and No. 2 Exhaust
    • No. 4 Intake and No. 3 Exhaust
    • No. 5 Intake and No. 6 Exhaust
    • No. 6 Intake and No. 7 Exhaust
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.