1989 Ford Probe GL, AutomaticFACTORY OEM SERVICE PROCEDURE

Normally Open Valves

Normally open valves are available with or without vacuum vents. Valves without vents release air for 1.1-2.8 seconds when a sudden high vacuum of about 20 in. Hg is applied to the signal port. This prevents backfiring during deceleration.

Normally open valves with a vacuum vent release air at intervals during deceleration, and when a vacuum pressure difference is maintained between signal port and vent port. The signal port must have 3 in. Hg more vacuum than vent port. The pressure difference, along with timed release of air during these stages, prevents catalyst from overheating.

Fig 1: Normally Open Air By-Pass Valve
G55740Courtesy of FORD MOTOR CO.