1989 Ford Bronco II RWD, Standard, M5OD-R1FACTORY OEM SERVICE PROCEDURE
Ignition Timing - Computed Timing
- Ensure ignition is OFF. Wait 10 seconds then activate KEY ON ENGINE RUNNING (KOER) SELF-TEST. For KOER SELF-TEST see the appropriate TESTS W/CODES article in the ENGINE PERFORMANCE section. Start engine and check computed timing after the last service code has been displayed.
- The timing will remain fixed for 2 minutes unless SELF-TEST is deactivated. Computed timing is equal to the base timing plus 17-23 degrees BTDC. If computed timing is not within specifications, see appropriate TESTS W/CODES article in the ENGINE PERFORMANCE section.