1989 Ford Bronco II RWD, Standard, M5OD-R1FACTORY OEM SERVICE PROCEDURE

Ignition Timing - Computed Timing

  1. Ensure ignition is OFF. Wait 10 seconds then activate KEY ON ENGINE RUNNING (KOER) SELF-TEST. For KOER SELF-TEST see the appropriate TESTS W/CODES article in the ENGINE PERFORMANCE section. Start engine and check computed timing after the last service code has been displayed.
  2. The timing will remain fixed for 2 minutes unless SELF-TEST is deactivated. Computed timing is equal to the base timing plus 17-23 degrees BTDC. If computed timing is not within specifications, see appropriate TESTS W/CODES article in the ENGINE PERFORMANCE section.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.