1987 Ford Bronco II 4WD V6-177 2.9LFACTORY OEM SERVICE PROCEDURE

Compressor

Fig. 35 Motorcraft FS-6 six cylinder compressor removal:

Factory service manual diagram






1. Disconnect battery ground cable.
2. Discharge refrigerant from system.
3. Disconnect wire connector from clutch field coil connector.
4. Disconnect refrigerant lines from compressor manifolds and cap all open lines.
5. Loosen pivot bolt and remove front and rear adjusting bolts and remove drive belt, Fig. 35.
6. Remove pivot bolt and remove compressor with front and rear braces attached from mounting bracket and vehicle.
7. Remove three screws from front brace and two screws from rear brace and remove both braces from compressor.
8. Reverse procedure to install. Use new O-rings lubricated with refrigerant oil.
9. Leak test, evacuate and charge system. Check system for proper operation.


Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.