1980 Ford FiestaFACTORY OEM SERVICE PROCEDURE

Normally Closed Valve

  1. With engine idling at normal operating temperature and ambient air above 65Β°F (18Β°C), disconnect vacuum hose to thermactor air by-pass valve. If air dumps to atmosphere through exhaust ports in silencer cover, hose connections are correct. Reconnect vacuum hose.
  2. Disconnect vacuum supply hose from bottom fitting of solenoid valve and check for manifold vacuum. If no vacuum, check and/or replace vacuum source hose as required. Reconnect vacuum hose. (Vacuum supply ALWAYS goes to bottom fitting on solenoid vacuum valve.)
  3. Disconnect wires to solenoid vacuum valve and determine which wire has B+ voltage with ignition switch in RUN position. Connect B+ wire to solenoid vacuum valve. With engine idling, ground other exposed terminal on valve. Air should NOT dump to atmosphere.
  4. Connect wires as originally installed and note that thermactor air is NOT being dumped to atmosphere. Replace solenoid valve if air dumps in either solenoid test.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.