Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
All Models
Check continuity between switch terminals as shown in Fig 1 through Fig 8. An ohmmeter must be used to test both systems. To detect marginal operation of the switch, move control knob while each reading is being taken. If switch does not indicate continuity as shown or poor continuity exists during movement, replace switch.
| Switch Position | Terminal Continuity |
|---|---|
| Off (Park) | P-L |
| Low | B-L |
| High | B-H |
| Wash | B-W |
| Switch Position | Terminal Continuity |
|---|---|
| Off (Park) | B-C, A-H, F-G |
| Low | C-D, A-G-H |
| High | D-E, A-G-H |
| Wash | W1-W2 |
| Off (Park) | B-C, A-H, F-G |
| Low | C-D-F-G, A-H |
| High | D-E-F-G, A-H |
| Intermittent | A-H, C-D-F-G |
| Wash | W1-2 |
Variable resistance between F and G: Minimum of between 100-900 ohms, to a maximum of 5, 600-8, 400 ohms.
| Switch Position | Terminal Continuity |
|---|---|
| Off (Park) | 1-5, 3-7 |
| Low | 1-4, 2-7 |
| High | 1-4, 2-6 |
| Wash | W1-W2 |
Variable resistance between F and G Minimum of between 100-900 ohms, to a maximum of 8, 000-13, 000 ohms.
| Switch Position | Terminal Continuity |
|---|---|
| Ford Zephyr Interval Wiper Off (Park) | B-H |
| Low | B-L |
| High | B-H-L |
| Intermittent | B-l |
| Wash | B-W |
Variable resistance between R-1 and R-2: Minimum 300 ohms, Maximum 15, 000 ohms. Fairmont and Zephyr only.
| Switch Position | Terminal Continuity |
|---|---|
| Off (Park) | C-D, A-B |
| Low | A-B-C |
| High | A-B-E |
| Wash | W1-W2 |
| Off (Park) | A-B, D-E |
| Low | A-B, D-E-F |
| High | D-E-F, A-B-C |
| Intermittent | E-F, A-B |
| Wash | W1-W2 |
Variable resistance between D and E: Minimum of between 480-720 ohms, to a maximum of 5, 600-8, 400 ohms.
| Switch Position | Terminal Continuity |
|---|---|
| Off (Park) | 28-58 |
| Low | 58-63 |
| High | 63-56 |
| Wash | 941-950 |
Variable resistance between F and G Minimum of between 100-900 ohms, to a maximum of 8, 000-13, 000 ohms.
| Switch Position | Terminal Continuity |
|---|---|
| Off (Park) | 58-63, 28-63 |
| Intermittent | 58-63 |
| Low | 58-63, 28-57 |
| High | 63-56, 28-57 |
| Wash | 941-950 |
| Switch Position | Terminal Continuity |
|---|---|
| Off (Park) | A-E |
| Intermittent | B-E-F |
| Low | B-E-F-C |
| High | D-B-F-C |
| Wash | W1-W2 |
Variable resistance between 63 and 57 (switch off): Between 1, 500 to 3, 000 ohms minimum and 28, 000 to 42, 000 ohms maximum.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.