The following procedure explains how to calibrate the Forward Facing Camera-HALF (FFC-HALF) when replacing the FFC-HALF (a replacement FFC-HALF is not factory calibrated). This procedure should also be used when the windshield is replaced.
Perform the following checks and setup prior to performing the calibration procedure:
- Confirm that the vehicle is unloaded (no luggage or extra weight being carried).
- Check and correct the tire pressures as needed.
- Check that the windshield is free of damage, is clean and that there are no impediments to the vision of the FFC-HALF.
- Place the vehicle on level ground and in good light.
- Align the wheels to the longitudinal axis of the car.
The calibration procedure is performed by placing the equipment to two different distances from the FFC-HALF. The diagnostic scan tool will warn when changing its position.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.