Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2016 Fiat 500 Abarth Cabrio, Automatic TransFACTORY OEM SERVICE PROCEDURE
Module, Battery Pack Control (BPCM)
DIAGNOSTIC CODE INDEX
| DTC | Description |
|---|---|
| P00B2-00 | RADIATOR COOLANT TEMPERATURE SENSOR CIRCUIT RANGE/PERFORMANCE |
| P00B3-00 | RADIATOR COOLANT TEMPERATURE SENSOR CIRCUIT LOW |
| P00B4-00 | RADIATOR COOLANT TEMPERATURE SENSOR CIRCUIT HIGH |
| P0A1F-00 | BATTERY ENERGY CONTROL MODULE INTERNAL PERFORMANCE |
| P0A7F-00 | HYBRID/EV BATTERY PACK DETERIORATION |
| P0A80-00 | REPLACE HYBRID/EV BATTERY PACK |
| P0A95-00 | HIGH VOLTAGE FUSE "A" |
| P0A9C-00 | HYBRID/EV BATTERY TEMPERATURE SENSOR 1 CIRCUIT PERFORMANCE |
| P0A9D-00 | HYBRID/EV BATTERY TEMPERATURE SENSOR 1 CIRCUIT LOW |
| P0A9E-00 | HYBRID/EV BATTERY TEMPERATURE SENSOR 1 - CIRCUIT HIGH |
| P0AA1-00 | HYBRID BATTERY POSITIVE CONTACTOR CIRCUIT STUCK CLOSED |
| P0AA2-00 | HYBRID/EV BATTERY POSITIVE CONTACTOR CIRCUIT STUCK OPEN |
| P0AA4-00 | HYBRID BATTERY NEGATIVE CONTACTOR CIRCUIT STUCK CLOSED |
| P0AA5-00 | HYBRID/EV BATTERY NEGATIVE CONTACTOR CIRCUIT STUCK OPEN |
| P0AA6-00 | HYBRID BATTERY VOLTAGE SYSTEM ISOLATION FAULT |
| P0AA7-00 | HYBRID/EV BATTERY VOLTAGE ISOLATION SENSOR CIRCUIT |
| P0ABB-00 | HYBRID BATTERY PACK VOLTAGE SENSE 1 CIRCUIT PERFORMANCE |
| P0ABC-00 | HYBRID BATTERY PACK VOLTAGE SENSE 1 CIRCUIT LOW |
| P0ABD-00 | HYBRID BATTERY PACK VOLTAGE SENSE 1 CIRCUIT HIGH |
| P0AC1-00 | HYBRID BATTERY PACK CURRENT SENSOR 1 CIRCUIT LOW |
| P0AC2-00 | HYBRID BATTERY PACK CURRENT SENSOR 1 CIRCUIT HIGH |
| P0AC3-00 | HYBRID/EV BATTERY PACK CURRENT SENSOR 1 CIRCUIT INTERMITTENT/ERRATIC |
| P0AD9-00 | HYBRID BATTERY POSITIVE CONTACTOR CONTROL CIRCUIT/OPEN |
| P0ADA-00 | HYBRID/EV BATTERY POSITIVE CONTACTOR CONTROL CIRCUIT PERFORMANCE |
| P0ADB-00 | HYBRID BATTERY POSITIVE CONTACTOR CONTROL CIRCUIT LOW |
| P0ADC-00 | HYBRID BATTERY POSITIVE CONTACTOR CONTROL CIRCUIT HIGH |
| P0ADD-00 | HYBRID BATTERY NEGATIVE CONTACTOR CONTROL CIRCUIT/OPEN |
| P0ADE-00 | HYBRID/EV BATTERY NEGATIVE CONTACTOR CONTROL CIRCUIT PERFORMANCE |
| P0ADF-00 | HYBRID BATTERY NEGATIVE CONTACTOR CONTROL CIRCUIT LOW |
| P0AE0-00 | HYBRID BATTERY NEGATIVE CONTACTOR CONTROL CIRCUIT HIGH |
| P0AE2-00 | HYBRID/EV BATTERY PRECHARGE CONTACTOR CIRCUIT STUCK CLOSED |
| P0AE3-00 | HYBRID/EV BATTERY PRECHARGE CONTACTOR CIRCUIT STUCK OPEN |
| P0AE4-00 | HYBRID BATTERY PRECHARGE CONTACTOR CONTROL CIRCUIT |
| P0AE5-00 | HYBRID/EV BATTERY PRECHARGE CONTACTOR CONTROL CIRCUIT PERFORMANCE |
| P0AE6-00 | HYBRID BATTERY PRECHARGE CONTACTOR CONTROL CIRCUIT LOW |
| P0AE7-00 | HYBRID BATTERY PRECHARGE CONTACTOR CONTROL CIRCUIT HIGH |
| P0B0F-00 | HYBRID/EV BATTERY PACK CURRENT SENSOR 2 CIRCUIT PERFORMANCE |
| P0B10-00 | HYBRID/EV BATTERY PACK CURRENT SENSOR 2 CIRCUIT LOW |
| P0B11-00 | HYBRID/EV BATTERY PACK CURRENT SENSOR 2 CIRCUIT HIGH |
| P0B12-00 | HYBRID/EV BATTERY PACK CURRENT SENSOR 2 CIRCUIT INTERMITTENT/ERRATIC |
| P0B13-00 | HYBRID/EV BATTERY PACK CURRENT SENSOR 1/2 CORRELATION |
| P0B33-00 | HIGH VOLTAGE SERVICE DISCONNECT CIRCUIT |
| P0B3B-00 | HYBRID/EV BATTERY VOLTAGE SENSE 1 CIRCUIT |
| P0B3C-00 | HYBRID/EV BATTERY VOLTAGE SENSE 1 CIRCUIT PERFORMANCE |
| P0B3D-00 | HYBRID/EV BATTERY VOLTAGE SENSE 1 CIRCUIT LOW |
| P0B3E-00 | HYBRID/EV BATTERY VOLTAGE SENSE 1 CIRCUIT HIGH |
| P0BBE-00 | HYBRID/EV BATTERY PACK VOLTAGE VARIATION EXCEEDED LIMIT |
| P0C32-00 | HYBRID/EV BATTERY COOLING SYSTEM PERFORMANCE |
| P0C43-00 | HYBRID BATTERY PACK COOLANT INLET TEMPERATURE SENSOR CIRCUIT RANGE/PERFORMANCE |
| P0C44-00 | HYBRID BATTERY PACK COOLANT INLET TEMPERATURE SENSOR CIRCUIT LOW |
| P0C45-00 | HYBRID BATTERY PACK COOLANT INLET TEMPERATURE SENSOR CIRCUIT HIGH |
| P0C4D-00 | HYBRID/EV BATTERY PACK COOLANT PUMP SUPPLY VOLTAGE CIRCUIT HIGH |
| P0C76-00 | HYBRID/EV SYSTEM DISCHARGE TIME TOO LONG |
| P0C77-00 | HV BATTERY SYSTEM PRECHARGE TIME TOO SHORT |
| P0C78-00 | HYBRID/EV BATTERY SYSTEM PRECHARGE TIME TOO LONG |
| P0CA6-00 | HYBRID/EV BATTERY CHARGING CURRENT HIGH |
| P0CA7-00 | HYBRID/EV BATTERY DISCHARGING CURRENT HIGH |
| P0CD6-00 | HYBRID BATTERY PACK COOLANT OUTLET TEMPERATURE SENSOR CIRCUIT RANGE/PERFORMANCE |
| P0CD7-00 | HYBRID BATTERY PACK COOLANT OUTLET TEMPERATURE SENSOR CIRCUIT LOW |
| P0CD8-00 | HYBRID BATTERY PACK COOLANT OUTLET TEMPERATURE SENSOR CIRCUIT HIGH |
| P0CE2-00 | HYBRID/EV BATTERY PACK COOLANT CONTROL VALVE 1 CONTROL CIRCUIT LOW |
| P0CE3-00 | HYBRID/EV BATTERY PACK COOLANT CONTROL VALVE 1 CONTROL CIRCUIT HIGH |
| P0CEA-00 | HYBRID/EV ELECTRONICS COOLANT PUMP PERFORMANCE |
| P0D1D-00 | HYBRID/EV BATTERY PACK COOLANT CONTROL VALVE 2 CONTROL CIRCUIT LOW |
| P0D1E-00 | HYBRID/EV BATTERY PACK COOLANT CONTROL VALVE 2 CONTROL CIRCUIT HIGH |
| P0DAB-00 | HYBRID/EV BATTERY CELL BALANCING PERFORMANCE |
| P0DE6-00 | HYBRID/EV BATTERY PACK CELL VOLTAGE LOW |
| P0DE7-00 | HYBRID/EV BATTERY PACK CELL VOLTAGE HIGH |
| P0E13-00 | HYBRID/EV BATTERY PACK COOLANT HEATER 1 CONTROL CIRCUIT LOW |
| P0E15-00 | HYBRID/EV BATTERY PACK COOLANT HEATER "A" CONTROL PERFORMANCE |
| P0E1F-00 | HYBRID/EV BATTERY PACK COOLANT PUMP 1 CONTROL CIRCUIT DRIVER CURRENT/TEMPERATURE TOO HIGH |
| P0E2E-00 | BATTERY CHARGER FUSE |
| P0E3B-00 | HYBRID/EV BATTERY COOLANT PUMP OVERSPEED |
| P0E43-00 | HYBRID/EV POWERTRAIN CONTROL MODULE B |
| P1500-00 | ECU CONFIGURATION MISMATCH |
| P167B-00 | CONTROLLED SYSTEM SHUTDOWN |
| P1A01-00 | BATTERY ENERGY CONTROL MODULE EEPROM FAILURE |
| P1A0C-00 | BATTERY ENERGY CONTROL MODULE SYSTEM VOLTAGE LOW |
| P1A0D-00 | BATTERY ENERGY CONTROL MODULE SYSTEM VOLTAGE HIGH |
| P1A13-00 | HYBRID/EV BATTERY CONTACTORS CONTROL CIRCUIT PERFORMANCE |
| P1A1B-00 | LINK VOLTAGE SENSOR CIRCUIT PERFORMANCE |
| P1A1C-00 | LINK VOLTAGE SENSOR CIRCUIT LOW |
| P1A1D-00 | LINK VOLTAGE SENSOR CIRCUIT HIGH |
| P1A1F-00 | BATTERY ENERGY CONTROL MODULE HV BATTERY SYSTEM VOLTAGE LOW |
| P1A21-00 | HV BATTERY CONTACTOR CONTROL SEQUENCE INCORRECT |
| P1A4E-00 | BATTERY ENERGY CONTROL MODULE HV BATTERY SYSTEM VOLTAGE HIGH |
| P1ABE-00 | BATTERY ENERGY CONTROL MODULE HYBRID BATTERY PACK OVERTEMPERATURE |
| P1AE2-00 | BATTERY ENERGY CONTROL MODULE HIGH VOLTAGE SYSTEM INTERLOCK CIRCUIT |
| P1AE3-00 | BATTERY ENERGY CONTROL MODULE HIGH VOLTAGE SYSTEM INTERLOCK CIRCUIT LOW |
| P1AE4-00 | BATTERY ENERGY CONTROL MODULE HIGH VOLTAGE SYSTEM INTERLOCK CIRCUIT HIGH |
| P1AE5-00 | HYBRID/EV BATTERY POWER OFF CIRCUIT |
| P1D0A-00 | BATTERY COOLANT HEATER CONTROL LINE ENABLED CIRCUIT SHORT TO GROUND |
| P1D0B-00 | BATTERY COOLANT HEATER CONTROL LINE ENABLED CIRCUIT SHORT TO BATTERY |
| P1E19-00 | HYBRID/EV BATTERY MODULE OVER TEMPERATURE |
| P1E25-00 | HYBRID/EV BATTERY FAILURE LEVEL 2 |
| P1E1A-00 | HYBRID/EV BATTERY CONTROL BOARD HARDWARE PERFORMANCE |
| P1E1B-00 | HYBRID/EV BATTERY SIDE VOLTAGE SYSTEM ISOLATION |
| P1E1D-00 | CONTROL MODULE IMPROPER WAKE-UP PERFORMANCE |
| U0140-00 | LOST COMMUNICATION WITH BODY CONTROL MODULE |
| U0335-00 | SOFTWARE INCOMPATIBILITY WITH HYBRID/EV BATTERY PACK SENSOR MODULE |
| U1015-00 | INTERNAL CAN COMMUNICATION BUS OFF |
| U11C5-00 | BPCM LOST COMMUNICATION WITH ON BOARD CHARGING MODULE |
| U1200-00 | LOST COMMUNICATION WITH POWER INVERTER MODULE |
| U1202-00 | LOST COMMUNICATION WITH ELECTRIC VEHICLE CONTROL UNIT |
| U1488-00 | IMPLAUSIBLE DATA RECEIVED FROM ELECTRIC VEHICLE CONTROL UNIT |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.