1997 Eagle Talon Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Circuit Test: A/T

  1. Ensure transmission gear selector is in Park or Neutral. Using DRB scan tool, read park/neutral position switch sense. If park/neutral position switch senses park position, go to next step. If park/neutral position switch does not sense park position, repair open park/neutral switch ground circuit.
  2. Disconnect starter relay and ensure connector is clean and not damaged. See Fig 1 . Using scan tool in voltmeter mode, check voltage at starter relay connector terminal No. 5 (Red/Black wire). See Figure . If voltage is more than 11.6 volts, go to next step. If volt age is 11.6 volts or less, repair open Red/Black wire.
  3. Using scan tool in voltmeter mode, check voltage at starter relay connector terminal No. 1 (Black/Red wire). See Figure . Check voltage with ignition switch in START position. If voltage is more than 10 volts, go to next step. If voltage is 10 volts or less, repair open Black/Red wire.
    Fig 1: Locating Starter Relay
    G95I14504Courtesy of CHRYSLER CORP.
Chapter Navigation
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.