Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1995 Eagle Summit DLFACTORY OEM SERVICE PROCEDURE
Code 62: Induction Control Valve Position Sensor
NOTE:
For component terminal identification, see TERMINAL IDENTIFICATIONΒ in this article. For appropriate WIRING DIAGRAMS, see WIRING DIAGRAMSΒ section. Induction control valve position sensor is built into induction control motor.
- Disconnect induction control motor connector and PCM connector. Ground PCM connector terminal No. 61. Using DVOM, check continuity between chassis ground and induction control motor connector terminal No. 1.
- Ground PCM connector terminal No. 111. Check continuity between chassis ground and induction control motor connector terminal No. 2.
- Ground PCM connector terminal No. 103. Check continuity between chassis ground and induction control motor connector terminal No. 4.
- If continuity exists in previous steps, go to next step. If continuity does not exist in previous steps, check for open or short to ground in appropriate circuit between PCM connector and induction control motor.
- With induction control motor connector disconnected, check continuity between chassis ground and induction control motor connector terminal No. 3. If continuity does not exist, repair wiring harness as necessary. If continuity exists, go to next step.
- Turn ignition switch to ON position. Ensure control motor connector is disconnected and PCM connector is connected. Using DVOM, check voltage at induction control motor connector terminals No. 2 and No. 4. If voltage is not 4.8-5.2 volts, repair wiring harness as necessary. If wiring harness is okay, replace PCM. If voltage is as specified, go to next step.
- Ensure ignition switch is in ON position. Ensure control motor connector is disconnected and PCM connector is connected. Using DVOM, check voltage at induction control motor connector terminal No. 1. If voltage is not 4.8-5.2 volts, repair wiring harness as necessary. If wiring harness is okay, replace PCM. If voltage is as specified, test is complete. Intermittent problem may exist. See TESTS W/O CODES - 2.4L article. If wiring harness, connectors and induction control motor are okay, replace air intake plenum assembly. See 2.4L 4-CYL VIN [G] article in ENGINES section.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.