1993 Eagle Vision ESiFACTORY OEM SERVICE PROCEDURE

Test 41A - Inoperative (Courtesy Light) Bulb

NOTE: For connector terminal identification, see CONNECTOR IDENTIFICATIONΒ  . For appropriate wiring diagram, see WIRING DIAGRAMSΒ  at end of article.

Remove inoperative (courtesy light) bulb. If bulb filament is open, replace bulb. Perform VERIFICATION PROCEDURE VER-1. If bulb filament is okay, disconnect inoperative light assembly. With DRB-II in voltmeter mode, check voltage on light assembly connector fused battery feed circuit (Pink wire). If voltage is more than 10 volts, repair open ground circuit for inoperative light assembly. Perform VERIFICATION PROCEDURE VER-1. If voltage is less than 10 volts, repair open circuit in Pink wire to inoperative courtesy light. Perform VERIFICATION PROCEDURE VER-1.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.