Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1998 Dodge and Ram Viper GTS-RFACTORY OEM SERVICE PROCEDURE
Bus Failure Messages
WARNING: This page is about a different car, the 2001 Dodge Viper and 2000 Dodge Viper. However, it is still accessible from the selected car via links, so may be relevant.
- Short-To-Battery
Either or both of the bus wires are shorted to the battery potential. - Short-To-5 Volts
Either or both of the bus wires are shorted to a 5-volt potential. - Short-To-Ground
Either or both of the bus wires are shorted to the ground. - BUS (+) & BUS (-) Shorted Together
The two bus wires are shorted together. - No Termination
The bus system has lost connection with all of its terminators. - Bus Bias Level Too Low
Either or both of the bus wire potentials are significantly below their normal 2.5 volts. - Bus Bias Level Too High
Either or both of the bus wire potentials are significantly above their normal 2.5 volts. - No BUS Bias
The bus system has lost connection with all modules that provide bias. - Bus (+) Open
The bus (+) wire has lost connection with termination and/or bias. - Bus (-) Open
The bus (-) wire has lost connection with termination and/or bias. - Not Receiving BUS Messages Correctly
The DRBIII(R) cannot communicate over the bus and does not know why.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.