Exhaust System: Muffler: Installation

  1. Position the muffler section in rubber exhaust hangers.
    Fig 1: Positioning Muffler In Rubber Exhaust Hangers
    G01860522Courtesy of DAIMLERCHRYSLER CORP.
  2. Install the bolts in the center exhaust flange (2). Tighten the bolts to 20 N.m (15 ft. lbs.).
    Fig 2: Installing Bolts In Center Exhaust Flange
    G01860523Courtesy of DAIMLERCHRYSLER CORP.
  3. Connect the ground strap (1) at the muffler and tail pipe. Tighten the ground strap bolt to 10 N.m (89 in. lbs.).
    Fig 3: Connecting Ground Strap At Muffler & Tail Pipe
    G01860524Courtesy of DAIMLERCHRYSLER CORP.
  4. Remove the support.
  5. Lower the vehicle.