2001 Chrysler Intrepid (CANADA) V6-3.2LFACTORY OEM SERVICE PROCEDURE

Alternator: Service and Repair

Fig.2 Generator:

Factory service manual diagram



REMOVAL
1. Disconnect negative battery cable (Fig. 2).
2. Loosen lower mounting bolt do not remove.
3. Remove the upper radiator support and relocate.
4. Loosen the lower mounting bolt, but do not remove
5. Loosen pivot bolt, but do not remove.
6. Loosen belt adjustment bolt.
7. Remove the generator drive belt. Refer to the Cooling System.
8. Remove support strut.
9. Remove lower mounting bolt.
10. Disconnect the generator field circuit plug.
11. Remove the B+ terminal nut and wire.
12. Remove pivot bolt.
13. Remove generator.

INSTALLATION
1. Install generator.
2. Install the pivot bolt.
3. Install the lower mounting bolt.
4. Connect the B+ wire and tighten nut and tighten to 9.8 Nm (85 ± 15 in. lbs.).
5. Connect the generator field circuit connector.
6. Install support bracket and tighten bolts.
7. Install generator drive belt. Refer to the Cooling System.
8. Tighten the pivot bolt.
9. Tighten the lower mounting bolt.
10. Install the upper radiator support and tighten bolts.
11. Connect the negative battery cable.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.