2000 Chrysler Intrepid (CANADA) V6-3.2LFACTORY OEM SERVICE PROCEDURE
HVAC Blend, Mode, and Recirculation Door Operation
The trouble codes that indicate a stall failure or a feedback signal failure work together to show what is wrong with the HVAC system. The stall trouble codes mean that the body control module cannot force an actuator to the end of the HVAC unit door.
Internal problems in the body control module will set other short-related codes. Having only stall trouble codes indicates that there is a problem with an open or short circuit in the wiring, a bad actuator, a bad HVAC unit door or connecting linkage. It is important that the operation of the HVAC door be checked if an actuator is removed. This can be checked by rotating each unit door shaft to confirm that the door will stop at both ends of travel. The actuator itself has no stops. It must have the HVAC unit door to stop travel to pass a stall test.
A feedback signal failure can occur on the blend or mode door. The body control module monitors the feedback signal to check the position of the actuator. The body control module not only checks the level of the signal but also how much the voltage changes.
A feedback failure can occur if there is a short or open circuit in the wiring, a bad actuator, a bad body control module, a bad HVAC unit door or connecting linkage. The easiest way to diagnose this is to use the DRB to actuate the blend or mode door. Note that the feedback voltage of the actuator should smoothly change as the actuator is moved. A sudden change in the feedback voltage to a 5.0-volt or a 0.0-volt level indicates the actuator is bad. A fixed feedback voltage that is less than 5.0 volts or greater than 0.0 volts without a stall failure, or a short failure indicates that the actuator, the HVAC unit door, or a connecting mechanical linkage is jammed thereby preventing movement. A feedback signal voltage that stays ON 5.0 volts or 0.0 volts indicates a wiring or body control module problem. The feedback voltage should always be less than 5.0 volts and greater than 0.0 volts.
The feedback trouble code can also occur from lack of actuator travel. This can be checked by confirming that the feedback signal smoothly changes when the actuator is moved with the DRB. If the signal is OK, the door travel is not correct. The actuator must be removed and the HVAC unit door mechanically checked for proper operation. Typical problems that prevent door movement include screws dropped in the HVAC unit or warped doors. Replace any part that is found defective.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.