1999 Chrysler Sebring LXiFACTORY OEM SERVICE PROCEDURE

Programming RKE Transmitter Without Scan Tool

  1. Ensure ignition is off. Using a jumper wire, ground 16-pin Data Link Connector (DLC), terminal No. 1, or connect jumper wire between 16-pin DLC connector terminals No. 1 and 4. See Fig 1 . DLCs are located under instrument panel, to right of steering column.
    Fig 1: Identifying 16-Pin Data Link Connector (DLC) Terminals
    G98C11561Courtesy of DAIMLERCHRYSLER CORP.
  2. Close both doors. Turn ignition switch to ACC position, then turn back to LOCK position. Press any transmitter button 3 times within 10 seconds. Door will lock and unlock once. If programming a second transmitter, press any button 3 times on second transmitter within one minute of programming first transmitter. Door will again lock and unlock once.
  3. Programming mode will be cancelled under one of the following conditions:
    • Programming of 2 transmitters is completed.
    • One minute has passed since programming was completed.
    • Jumper wire is disconnected.
    • Ignition is turned off.
    • Any door is opened.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.